Please use this identifier to cite or link to this item: https://publication.npru.ac.th/jspui/handle/123456789/2507
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSiengsanoh, K.-
dc.contributor.authorTuscharoen, S.-
dc.contributor.authorReerong, K.-
dc.contributor.authorSodsai, T.-
dc.contributor.authorSaechai, R.-
dc.contributor.authorChaiphaksa, W.-
dc.date.accessioned2026-10-16T04:41:21Z-
dc.date.available2026-10-16T04:41:21Z-
dc.date.issued2026-08-28-
dc.identifier.isbn978-974-7063-49-3-
dc.identifier.urihttps://publication.npru.ac.th/jspui/handle/123456789/2507-
dc.description.abstractThis research aims to investigate the attenuation behavior of gamma rays passing through aluminum foil absorbers of varying thicknesses. A comparative study was conducted between low-energy gamma rays from an Americium-241 (Am-241, 59.5 keV) source and medium-energy gamma rays from a Cesium-137 (Cs-137, 662 keV) source. The measurement system consisted of a Canberra NaI(Tl) scintillation detector (Model 802-2X2) connected to a processing system via Genie 2000 Spectroscopy Software, with a fixed counting time of 500 seconds. The results of the Net Peak Area analysis indicated that the attenuation behavior is significantly related to the energy level of the radiation. The main energy peak area of Am-241 showed a continuous downward trend, decreasing from 78,753 to 58,379 counts as the number of aluminum foil layers increased from 0 to 5 (total thickness of 0.15 mm). This reduction is attributed to the influence of the photoelectric effect in low-energy gamma radiation. Conversely, the main energy peak area of Cs-137 remained relatively constant across all thickness levels of the aluminum foil, indicating that aluminum foil with a thickness not exceeding 0.15 mm does not affect the attenuation of high-energy gamma rays.In conclusion, aluminum foil significantly affects the attenuation of low-energy gamma rays. These findings are beneficial for evaluating the influence of aluminum foil thickness in the detector's entrance window on the measurement accuracy of radiation across different energy levels.en_US
dc.publisherProceedings of the 18th NPRU National Academic Conferenceen_US
dc.relation.ispartofseries;502-510-
dc.subjectGamma-ray attenuationen_US
dc.subjectAluminum foilen_US
dc.subjectAm-241en_US
dc.subjectCs-137en_US
dc.titleA Comparative Study of Gamma-Ray Attenuation for Low and High Gamma Energy Sources through Aluminum Foil using Scintillation Detectoren_US
dc.title.alternativeการศึกษาเปรียบเทียบการลดทอนรังสีแกมมาพลังงานต่ำและพลังงานสูงโดยแผ่นอะลูมิเนียมฟอยล์ด้วยหัววัดรังสีแบบซินทิลเลชันen_US
dc.typeOtheren_US
Appears in Collections:Proceedings of the 18th NPRU National Academic Conference

Files in This Item:
File Description SizeFormat 
502.pdfSCI-P152.74 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.