Please use this identifier to cite or link to this item:
https://publication.npru.ac.th/jspui/handle/123456789/2506Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Siengsanoh, K. | - |
| dc.contributor.author | Tuscharoen, S. | - |
| dc.contributor.author | Phomfai, T. | - |
| dc.contributor.author | kaewsaiharn, N. | - |
| dc.contributor.author | Oakkhiwarakon, S. | - |
| dc.contributor.author | Sriton, T. | - |
| dc.contributor.author | Jomkaew, T. | - |
| dc.contributor.author | Phetphraprasert, S. | - |
| dc.contributor.author | Songka, S. | - |
| dc.contributor.author | Chaiphaksa, W. | - |
| dc.date.accessioned | 2026-10-16T04:38:34Z | - |
| dc.date.available | 2026-10-16T04:38:34Z | - |
| dc.date.issued | 2026-08-28 | - |
| dc.identifier.isbn | 978-974-7063-49-3 | - |
| dc.identifier.uri | https://publication.npru.ac.th/jspui/handle/123456789/2506 | - |
| dc.description.abstract | This research investigates the effect of collimator size on gamma-ray measurements using a sodium iodide scintillation detector doped with thallium (NaI(Tl)). The gamma-ray sources used in this study were Americium-241 with an energy of 59.5 keV and Cesium-137 with an energy of 662 keV. The collimator sizes tested were 4, 7, 9, and 13 millimeters, including a condition without a collimator. The measured parameters included spectral count rate and energy resolution. The results showed that, for Americium-241, the spectra obtained with 9 mm, 13 mm, and without a collimator yielded the highest count rates, while the 4 mm collimator produced the lowest count rate. In terms of energy resolution, the 4 mm collimator provided the lowest full width at half maximum (FWHM), indicating the best energy discrimination and highest performance. In contrast, measurements without a collimator resulted in the highest FWHM values For Cesium-137, the results followed a similar trend. The highest count rate was observed without a collimator, while the 4 mm collimator yielded the lowest count rate. The energy resolution also showed consistent behavior, with the 4 mm collimator providing the lowest FWHM. Overall, the energy resolution tended to worsen (increase in FWHM) as the collimator aperture size increased, with the no-collimator condition giving the highest FWHM values. | en_US |
| dc.publisher | Proceedings of the 18th NPRU National Academic Conference | en_US |
| dc.relation.ispartofseries | ;495-501 | - |
| dc.subject | Spectral count rate | en_US |
| dc.subject | Energy resolution Americium-241 | en_US |
| dc.title | study of the effect of collimator size on the efficiency of gamma radiation measurements using a scintillation detector | en_US |
| dc.title.alternative | การศึกษาผลกระทบขนาดของคอลลิเมเตอร์ที่มีต่อประสิทธิภาพในการวัดทางรังสีแกมมาด้วย หัววัดซินทิลเลชัน | en_US |
| dc.type | Other | en_US |
| Appears in Collections: | Proceedings of the 18th NPRU National Academic Conference | |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.