Please use this identifier to cite or link to this item: https://publication.npru.ac.th/jspui/handle/123456789/2506
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSiengsanoh, K.-
dc.contributor.authorTuscharoen, S.-
dc.contributor.authorPhomfai, T.-
dc.contributor.authorkaewsaiharn, N.-
dc.contributor.authorOakkhiwarakon, S.-
dc.contributor.authorSriton, T.-
dc.contributor.authorJomkaew, T.-
dc.contributor.authorPhetphraprasert, S.-
dc.contributor.authorSongka, S.-
dc.contributor.authorChaiphaksa, W.-
dc.date.accessioned2026-10-16T04:38:34Z-
dc.date.available2026-10-16T04:38:34Z-
dc.date.issued2026-08-28-
dc.identifier.isbn978-974-7063-49-3-
dc.identifier.urihttps://publication.npru.ac.th/jspui/handle/123456789/2506-
dc.description.abstractThis research investigates the effect of collimator size on gamma-ray measurements using a sodium iodide scintillation detector doped with thallium (NaI(Tl)). The gamma-ray sources used in this study were Americium-241 with an energy of 59.5 keV and Cesium-137 with an energy of 662 keV. The collimator sizes tested were 4, 7, 9, and 13 millimeters, including a condition without a collimator. The measured parameters included spectral count rate and energy resolution. The results showed that, for Americium-241, the spectra obtained with 9 mm, 13 mm, and without a collimator yielded the highest count rates, while the 4 mm collimator produced the lowest count rate. In terms of energy resolution, the 4 mm collimator provided the lowest full width at half maximum (FWHM), indicating the best energy discrimination and highest performance. In contrast, measurements without a collimator resulted in the highest FWHM values For Cesium-137, the results followed a similar trend. The highest count rate was observed without a collimator, while the 4 mm collimator yielded the lowest count rate. The energy resolution also showed consistent behavior, with the 4 mm collimator providing the lowest FWHM. Overall, the energy resolution tended to worsen (increase in FWHM) as the collimator aperture size increased, with the no-collimator condition giving the highest FWHM values.en_US
dc.publisherProceedings of the 18th NPRU National Academic Conferenceen_US
dc.relation.ispartofseries;495-501-
dc.subjectSpectral count rateen_US
dc.subjectEnergy resolution Americium-241en_US
dc.titlestudy of the effect of collimator size on the efficiency of gamma radiation measurements using a scintillation detectoren_US
dc.title.alternativeการศึกษาผลกระทบขนาดของคอลลิเมเตอร์ที่มีต่อประสิทธิภาพในการวัดทางรังสีแกมมาด้วย หัววัดซินทิลเลชันen_US
dc.typeOtheren_US
Appears in Collections:Proceedings of the 18th NPRU National Academic Conference

Files in This Item:
File Description SizeFormat 
495.pdfSCI-P112.41 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.