Abstract: The study presents an experimental investigation of the reduction of energy consumption. in a refrigeration system ( water cooler) employing a passive evaporative cooling device ( PECD) . The PECD is placed on the top of compressor of water cooler to cool the compressor. Under of fixed indoor air condition (30 C; 67% (relative humidity), the performance of the water cooler before and after PECD installation was compared. A decrease in power consumption of the unit is observed, with concomitant increases in coefficient of performance (COP). In addition, results obtained show that up to 17% increase in COP, and a 2. 3% decrease in power consumption can be achieved by employing PECD. Additionally, the COP was found to increase by about 5.48% for every 1 C drop in refrigerant condensing temperature.
URI: https://publication.npru.ac.th/jspui/handle/123456789/2137
ISBN: 978-974-7063-46-2
Appears in Collections:Proceedings of the 16th NPRU National Academic Conference

Files in This Item:
File Description SizeFormat 
NPRU_Conference_Proceeding_16_Final_หน้า_440-448.pdf695.95 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.